VRF systems, one plant for every zone

A variable refrigerant flow system runs many indoor units from one outdoor plant. Each zone sets its own temperature and the inverter compressor delivers only what the building is asking for.

A row of Midea VRF outdoor units on a terrace beside a glass facade
VRF outdoor units on a commercial terrace
Typical office setpointTypical
Holds
24 ± 1 °C
Note
held zone by zone from one outdoor system

What is included

Everything below can be taken as one design and build contract or as separate packages.

Where it fits

  • Offices
  • Hotels
  • Hospitals
  • Showrooms
  • Restaurants
  • Villas
  • Load calculation and system selection
  • Outdoor and indoor unit layout
  • Refrigerant piping, brazing and nitrogen purging
  • Pressure testing and vacuuming
  • Refrigerant charging by calculation
  • Drain piping and condensate pumps
  • Central and zone controllers, BMS gateways
  • Commissioning reports and user handover

How we approach it

Why VRF suits mixed buildings

Cabins, conference rooms and open bays rarely need cooling at the same time. With VRF each indoor unit is controlled on its own, so empty rooms cost nothing and busy ones get full capacity. Indoor units come as cassettes, ducted, wall mounted or floor standing to suit the ceiling.

Piping decides the life of the system

Most VRF problems trace back to installation: dirty or oxidised joints, poor insulation, wrong pipe sizes or a guessed refrigerant charge. We braze under nitrogen, pressure test and hold a deep vacuum before charging, and record each step.

Controls and monitoring

Zone remotes for users, a central controller for the facility team, and gateways to the building management system where there is one. Schedules and setpoint limits stop the system running empty floors overnight.

At a glance

Typical figures; your project is designed to its own brief
System typesHeat pump, heat recovery
Indoor unitsCassette, ducted, wall, floor standing
Commissioning checksPressure hold, vacuum, charge, airflow, controls
IntegrationCentral controller, BMS via gateway

Common questions

What is the difference between VRF and VRV?

None in principle. VRV is a trademark of one manufacturer; VRF is the general name for the same technology.

Is VRF cheaper to run than split ACs?

Usually, in buildings where zones run at different loads, because the inverter plant runs at part load most of the day. The saving depends on the building and how it is used, so we estimate it during design rather than quote a fixed figure.

Can VRF be installed in an occupied building?

Yes. Piping can be run floor by floor and outdoor units commissioned in stages, which suits phased fit outs.

Planning a VRF system?

Send the location and what you need. An engineer calls back to fix a site visit, and the heat load comes before any quote.

  • PhoneNumber to confirm
  • WhatsAppNumber to confirm
  • EmailAddress to confirm
  • OfficeStreet address to confirm, Hyderabad, Telangana
  • HoursMonday to Saturday, 9:30 am to 6:30 pm to confirm

Please enter your name.

We call back on this number. Spaces and +91 are fine.

Enter a 10 digit mobile or a landline with STD code.

Choose the closest match.

Location, type of building, rough area, or the equipment you have now.

We use these details only to reply to this enquiry and keep them for up to 12 months. How we handle your data.