Chilled water plants for large buildings

When a building is too big for refrigerant piping, cooling is made centrally. Chillers cool water, pumps carry it through the building, and air handling units and fan coil units turn it into cool air where it is needed.

Air cooled screw chiller installed on a building rooftop, with chilled water pipework running along the parapet
Air cooled screw chiller, rooftop plant
Typical chilled waterTypical
Holds
7 °C
Note
supply to the coils, about 12 °C back to the chiller

What is included

Everything below can be taken as one design and build contract or as separate packages.

Where it fits

  • Hospitals
  • Malls
  • Campuses
  • IT parks
  • Hotels
  • Process cooling
  • Chiller selection: air cooled or water cooled
  • Cooling towers and condenser water systems
  • Primary and secondary pumping
  • Chilled water piping and insulation
  • Air handling units and fan coil units
  • Valves, balancing and expansion tanks
  • Controls and BMS integration
  • Testing, balancing and commissioning

How we approach it

Air cooled or water cooled

Air cooled chillers sit on the roof and reject heat straight to the outside air: simpler, no cooling tower, no water treatment. Water cooled chillers use a cooling tower and are more efficient, which pays off on large plants that run long hours, but they need water treatment and a plant room.

AHU and FCU

An air handling unit filters, cools and moves large volumes of air through ductwork to a whole floor or a theatre suite, often with fresh air. A fan coil unit is a small coil and fan serving one room or zone. Most buildings use both.

Balancing the water side

A chilled water plant only performs if every coil gets its design flow. We flush and pressure test the piping, set the balancing valves and record flows and temperatures at commissioning.

At a glance

Typical figures; your project is designed to its own brief
Chilled waterAbout 7 °C supply, 12 °C return
Chiller typesAir cooled and water cooled; screw, scroll, centrifugal
Air sideAHUs with filters and coils; FCUs per room
Capacity unitTR: 1 ton of refrigeration = 3.52 kW

Common questions

When does a chiller make more sense than VRF?

Generally in large buildings with long piping runs, many hours of operation, high fresh air loads or areas like operating theatres that need air handling units anyway. We compare both during design.

Can you replace an old chiller without shutting the building?

Often yes, with a temporary chiller or by replacing one machine at a time in a multi chiller plant. It is planned with the facility team around the building’s hours.

Do you maintain chillers you did not install?

Yes, under an AMC or CMC after an initial condition survey.

Planning a chilled water plant?

Send the location and what you need. An engineer calls back to fix a site visit, and the heat load comes before any quote.

  • PhoneNumber to confirm
  • WhatsAppNumber to confirm
  • EmailAddress to confirm
  • OfficeStreet address to confirm, Hyderabad, Telangana
  • HoursMonday to Saturday, 9:30 am to 6:30 pm to confirm

Please enter your name.

We call back on this number. Spaces and +91 are fine.

Enter a 10 digit mobile or a landline with STD code.

Choose the closest match.

Location, type of building, rough area, or the equipment you have now.

We use these details only to reply to this enquiry and keep them for up to 12 months. How we handle your data.