HVAC design that starts from the numbers

Before a single unit is ordered, we work out how much heat each room gains on Hyderabad’s worst afternoon and what it takes to remove it. The drawings and the bill of quantities follow from that.

Banks of VRF condensing units and split AC outdoor units on a red epoxy floor at an industrial site
VRF condensing units, industrial site
Outdoor design conditionTypical
Outside
40 °C
Note
Hyderabad summer peak, the starting point of every heat load

What is included

Everything below can be taken as one design and build contract or as separate packages.

Where it fits

  • New buildings
  • Office fit outs
  • Hospitals and labs
  • Factories
  • Retrofits and replacements
  • Villas
  • Site survey and measurement
  • Room by room heat load calculation
  • Fresh air and ventilation rates
  • System comparison: VRF, chilled water, ducted split
  • Duct and refrigerant or chilled water piping layouts
  • Equipment schedules and specifications
  • Bill of quantities and cost estimate
  • Tender support and bid comparison

How we approach it

Heat load, room by room

We calculate the cooling each room needs from its orientation, glass, walls and roof, the people and equipment inside, lighting, and the fresh air it must take in. Rules of thumb per square foot oversize some rooms and starve others; a real load sheet does not.

Choosing the system

The same building can be cooled by VRF, a chilled water plant or ducted units. We compare them on first cost, running cost, plant space, noise, phasing and maintenance, and put the recommendation in writing with the reasons.

Drawings you can build from

Layouts for ductwork and piping, schematics, equipment schedules and a bill of quantities with every item measured. Contractors can price it line by line, which makes quotes comparable.

At a glance

Typical figures; your project is designed to its own brief
Outdoor design basisHyderabad summer, about 40 °C dry bulb
Indoor comfortTypically 24 ± 1 °C, 50 to 60% RH
DeliverablesLoad sheets, layouts, schematics, schedules, BOQ
Capacity unitTR: 1 ton of refrigeration = 12,000 BTU/h = 3.52 kW

Common questions

Why not just size by square feet?

Two rooms of the same size can need very different cooling. A west facing glass cabin gains far more heat than an inner meeting room. Sizing by area alone leads to rooms that never cool and units that short cycle.

Can you design and also install?

Yes, and you can also take our design to tender. The BOQ is written so any qualified contractor can price it.

Do you design for green building ratings?

We can design to the efficiency and fresh air requirements your consultant sets for IGBC or GRIHA submissions and provide the equipment data they need.

Planning a new building or fit out?

Send the location and what you need. An engineer calls back to fix a site visit, and the heat load comes before any quote.

  • PhoneNumber to confirm
  • WhatsAppNumber to confirm
  • EmailAddress to confirm
  • OfficeStreet address to confirm, Hyderabad, Telangana
  • HoursMonday to Saturday, 9:30 am to 6:30 pm to confirm

Please enter your name.

We call back on this number. Spaces and +91 are fine.

Enter a 10 digit mobile or a landline with STD code.

Choose the closest match.

Location, type of building, rough area, or the equipment you have now.

We use these details only to reply to this enquiry and keep them for up to 12 months. How we handle your data.