HVAC glossary
The terms you will meet in our drawings, quotes and maintenance reports, in plain English.
- AHU (air handling unit)
- A large unit that filters, cools or heats, and moves air through ductwork to a floor or zone, often mixing in fresh air.
- Air balancing
- Measuring airflow at each outlet after installation and adjusting dampers until every one delivers its design airflow. Also called TAB.
- Air changes per hour (ACH)
- How many times the full volume of air in a room is replaced in an hour. Clean rooms and operating theatres need far more than offices.
- AMC
- Annual maintenance contract. Scheduled preventive visits and breakdown calls, with spare parts usually charged separately.
- BMS
- Building management system. Software and controllers that monitor and control HVAC and other services from one place.
- BOQ
- Bill of quantities. An itemised list of every material and piece of equipment with quantities, used to price and compare quotes.
- BTU/h
- British thermal units per hour, a unit of heat flow. 12,000 BTU/h equals 1 TR.
- CFM
- Cubic feet per minute, the usual unit for airflow through ducts, fans and diffusers.
- Chiller
- A machine that cools water for a central cooling system. The chilled water is pumped to AHUs and FCUs around the building.
- Clean room
- A room where airborne particles, pressure, temperature and humidity are controlled to a defined class, used in pharma, labs and electronics.
- CMC
- Comprehensive maintenance contract. Like an AMC, but spare parts listed in the contract are included.
- Condensing unit
- The outdoor part of a split or VRF system, containing the compressor and the coil that rejects heat to outside air.
- Cooling tower
- Equipment that rejects heat from a water cooled chiller by evaporating a small part of the condenser water into the air.
- Design condition
- The outdoor and indoor temperature and humidity an HVAC system is designed for. Outdoor values come from local weather data for the hottest periods.
- Diffuser
- The fitting at the end of a duct that spreads supply air into the room without drafts.
- Dry bulb temperature
- The air temperature a normal thermometer reads, without the effect of humidity.
- FCU (fan coil unit)
- A small unit with a coil and fan that cools one room or zone using chilled water from a central plant.
- Fire damper
- A device in a duct that closes automatically in a fire to stop flames and smoke passing through a fire rated wall or floor.
- Fresh air
- Outdoor air brought into a building for ventilation. It has to be cooled and dehumidified, so it is a large part of the heat load.
- GI duct
- Ductwork made from galvanised iron sheet, the most common duct material in Indian buildings.
- GMP
- Good manufacturing practice. Rules for making medicines that include clean room grades A to D.
- Heat load
- The amount of heat a room or building gains from sun, walls, glass, people, lights, equipment and fresh air. The cooling system is sized to remove it.
- Heat recovery VRF
- A VRF system that can cool some zones and heat others at the same time, moving heat between them.
- HEPA filter
- High efficiency particulate air filter. Grades H13 and H14 capture at least 99.95% and 99.995% of the most penetrating particle size.
- Inverter compressor
- A compressor whose speed varies with demand, so it runs slower at part load instead of switching on and off.
- IQ, OQ, PQ
- Installation, operational and performance qualification. The documented proof that a clean room HVAC system was installed and performs to specification.
- ISO 14644
- The international standard that classifies clean rooms by the number of airborne particles per cubic metre.
- Pressure cascade
- Keeping cleaner rooms at higher pressure than their neighbours so air flows from clean to less clean areas.
- Relative humidity (RH)
- How much moisture the air holds compared with the most it could hold at that temperature, as a percentage.
- Setpoint
- The temperature or humidity a controller is told to hold.
- SITC
- Supply, installation, testing and commissioning. The usual scope of an HVAC contract.
- SMACNA
- A widely used set of standards for duct construction, sealing and gauges.
- TR (ton of refrigeration)
- A unit of cooling capacity: the heat needed to melt one ton of ice in a day. 1 TR is 12,000 BTU/h or about 3.52 kW.
- VRF / VRV
- Variable refrigerant flow. One outdoor system feeds many indoor units through refrigerant piping, each controlled separately. VRV is one maker’s trademark for it.
A term we have not covered?
Ask us. If it comes up in a quote, it should be explained before you sign.