AVSTS Projects Pvt Ltd · HVAC engineers in Hyderabad since 2017

Cooling engineered for Hyderabad heat

We design, install and maintain VRF, chilled water, ducting and clean room systems for offices, hospitals, pharma plants, banks and retail across Telangana.

  • Design, SITC and AMC under one roof
  • Multi-brand
  • Clients from SBI to DMart
Air cooled screw chiller installed on a building rooftop, with chilled water pipework running along the parapet
Design basisHyderabad
Outside
40.0 °Cdry bulb, summer
Inside
24.0 °C± 1, office floor
Humidity
50 to 60% RH
Air cooled screw chiller, rooftop plant, installed by AVSTS.

Banks, supermarkets, campuses and hotels already run on our work

Twenty five organisations across Hyderabad, from bank branches and retail chains to a university and a medical college.

  • Anurag University
  • Srigayatri Educational Institutions
  • Neelima Institute of Medical Sciences
  • QnQ Pharmacy
  • DMart
  • Ushodaya Supermarkets
  • Vijetha Supermarkets
  • State Bank of India
  • Indian Bank
  • Union Bank of India
  • Indel Money
  • K Raheja Corp
  • Awfis
  • Flipspaces
  • Suvarna Technosoft
  • CADFEM
  • Mercure Hotels
  • Summer Green Resort
  • Nidhivan Indian Fine Dine
  • Fusion 9
  • Modi Properties
  • DSL Infrastructure and Space Developers
  • FTTC Projects
  • GK Builders and Developers
  • Geeta

Clients by sector and site photos

Room by room, the number we design to

Every system we build exists to hold one condition against Hyderabad’s summer. Here is what that means in the spaces we work in.

  1. Before anything is bought

    The drawing board

    40.0 °C Outside, dry bulb

    Outdoor design condition, Hyderabad summer

    Every heat load we calculate starts from the city’s summer peak. Hyderabad crosses 40 °C most years, so that is the number the system has to beat on its worst afternoon.

    HVAC design and heat load
  2. Offices, IT floors, showrooms

    Open office floor

    24.0 °C ± 1 °C · 50 to 60% RH

    Comfort cooling, zone by zone

    A VRF system lets each cabin and bay run its own temperature from one outdoor plant, and the inverter compressor slows down when the floor empties.

    VRF and VRV systems
  3. Pharma, labs, operating theatres

    Grade C clean room

    21.0 °C ± 2 °C · 45% RH, +15 Pa

    Filtered, pressurised, validated

    HEPA filtered air, a pressure cascade between rooms and temperature held to the product’s specification, tested and documented before production starts.

    Clean room HVAC
  4. Hospitals, campuses, malls

    Chilled water plant

    7.0 °C supply, 12 °C return

    Chillers feeding AHUs and fan coils

    For large buildings the cooling is made centrally: chillers send water out at about 7 °C to air handling units and fan coil units, and take it back at about 12 °C.

    Chillers, AHU and FCU
  5. Supermarkets, restaurants, kitchens

    Supermarket floor

    24.0 °C fresh air to every aisle

    Ducted air, balanced at every grille

    Big open floors and kitchens need air moved, not just cooled. We size, fabricate and balance the ductwork so the far aisle gets the same air as the entrance.

    Ducting and ventilation
  6. Three summers later

    The same office, year three

    24.0 °C ± 1 °C · still holding

    Planned maintenance under AMC or CMC

    Coils foul, filters load and refrigerant leaks slowly. Scheduled visits keep the setpoint where it was on handover day, with a service report after every visit.

    AMC and CMC

Seven steps from survey to service

The same sequence for one floor or a whole campus. The heat load comes before the quote, never after.

  1. Site visit

    We walk the building, measure, and note orientation, glazing, occupancy and what runs inside.

  2. Heat load

    Room by room heat load from the outdoor design condition to your indoor one.

  3. Concept

    System options compared on running cost, space, noise and phasing.

  4. Drawings

    Duct and piping layouts, schematics and equipment schedules.

  5. BOQ and estimate

    An itemised bill of quantities, so quotes can be compared line by line.

  6. SITC

    Supply, installation, testing and commissioning by our own teams.

  7. AMC or CMC

    Planned maintenance that keeps the handover numbers.

From our sites

Rooftop plant, terraces and plant rooms, photographed by our own teams.

A row of Midea VRF outdoor units on a terrace beside a glass facade
VRF outdoor units on a commercial terrace
Banks of VRF condensing units and split AC outdoor units on a red epoxy floor at an industrial site
VRF condensing units, industrial site
Two floor standing air conditioning units installed side by side in a plant room
Floor standing units in a plant room

All project photos

From a service centre to a design and build contractor

We learned HVAC from the maintenance end first, which is why our installations are built to be serviced.

  1. 2017

    Service centre

    Started in Hyderabad as an HVAC service centre: repairs, maintenance and after sales support.

  2. 2019

    Voltas showroom

    Opened a Voltas showroom and became a channel partner for leading air conditioning brands.

  3. 2022

    Private limited

    Incorporated as AVSTS Projects Pvt Ltd to take on larger design and build contracts.

Brands we install and service list to confirm

  • Voltas
  • Carrier
  • Midea
  • O General
  • Blue Star
  • Toshiba

Questions we get asked first

Something else? Ask in the form below or on WhatsApp.

Do you work only in Hyderabad?

Our office and teams are in Hyderabad and most of our sites are in Telangana. We take projects elsewhere in South India when the scope justifies travel; ask us with the location.

Can you work from an architect’s or consultant’s drawings?

Yes. We can execute an MEP consultant’s design as the HVAC contractor, or do the design ourselves. Either way we check the heat load before ordering equipment.

Which brands do you install?

We are multi-brand, so we recommend equipment on capacity, efficiency, service support and budget rather than one catalogue. Tell us if your organisation has an approved make list.

Do you service systems another contractor installed?

Yes. We start with a condition survey of the existing equipment and ductwork, then offer an AMC or CMC that covers what we found.

What do you need from me for a quote?

The site location, the type of building, floor plans or a rough area per floor, and whether it is a new installation, a replacement or maintenance. Photos of the existing plant help.

Tell us about the building.

Send the location and what you need. An engineer calls back to fix a site visit, and the heat load comes before any quote.

  • PhoneNumber to confirm
  • WhatsAppNumber to confirm
  • EmailAddress to confirm
  • OfficeStreet address to confirm, Hyderabad, Telangana
  • HoursMonday to Saturday, 9:30 am to 6:30 pm to confirm

Please enter your name.

We call back on this number. Spaces and +91 are fine.

Enter a 10 digit mobile or a landline with STD code.

Choose the closest match.

Location, type of building, rough area, or the equipment you have now.

We use these details only to reply to this enquiry and keep them for up to 12 months. How we handle your data.